Nguyen Thanh Hai * , Phan Quoc Dzung and Vo Viet Cuong

* Corresponding author (hai_nguyenthanh2012@yahoo.com.vn)

Main Article Content

This article has been retracted: please see CTUJoISD Policy on Article Retraction.

Following the receipt of a whistle-blower complaint, an investigation of this and related papers was conducted. This article has been retracted at the request of the Editor-in-Chief. The scientific integrity of this paper is not assured.

Abstract

This paper presents both the previously and newly modified Stator Flux Oriented Control (SFOC) with Pulse Width Modulation (PWM) and Hysteresis Current Controller (HCC) structures for Doubly Fed Induction Generator (DFIG) in wind turbines to improve responses of active power, reactive power and generator's torque during the grid voltage unbalance. In the proposed SFOC-based scheme, which emphasizes on improvement of generator's torque performance, PI controllers with Fuzzy logic, Notch filters and the Torque Stability Controller (TSC) are utilized. The other control techniques use single or multiple applications of PI controller with anti-windup, hybrid PI-Fuzzy controller with anti-windup and Notch filter to eliminate the second-order harmonic components. The designed system consists of a wound rotor induction generator and power-electronics converters at both rotor and grid sides. The modifications are applied to the rotor side converter (RSC). Simulations in Matlab/Simulink illustrate the enhanced stability of torque, active and reactive powers delivered by DFIG in both the SFOC-based and HCC-based schemes. Moreover, comparisons in simulation results, obtained separately from all the presented control structures, are provided to evaluate the effectiveness of the newly proposed scheme.

Keywords: DFIG, PWM, Hysteresis current controller, SFOC, Fuzzy logic

Article Details

References

Ackermann, T., 2003. Wind power in power systems; John Wiley and Sons, USA.

Alegría, M.I., Andreu, J., Martín, L.J., 2007. Connection requirement for wind farms: A survey on technical requirements and regulation. Renewable and Sustainable Energy Review. 11(8): 1858-1872.

Ghennam, T., Berkouk, E.M., Francois, B., 2007. A Vector Hysteresis Current Control Applied on Three-Level Inverter. Application to the Active and Reactive Power Control of Doubly Fed Induction Generator Based Wind Turbine. International Review of Electrical Engineering (I.R.E.E.), 20: 258-267.

Hai, N.T., 2014. Improved Control of DFIG Systems under Unbalanced Voltage Dip for Torque Stability Using PI-Fuzzy Controller. International Journal of Electrical Energy. 2(4): 300-307.5

Hai, N.T., 2015. Modified Controls for DFIG under Unbalanced Voltage for Eliminate Rotor Currents Harmonics Using PI-Fuzzy Controller. International Journal of Electrical Energy. 3(1): 6-12.

Hai, N.T., Cuong, V.V., 2015. Modified Controls for Doubly Fed Induction Generator under Unbalanced Voltage Distortion for Torque Stability and PI-Fuzzy Controller. Proceeding of 7th IEEE International Conference on CIS and RAM 2015, pp 65-70, 15-17 July, 2015, Angkor Wat, Cambodia.

Jiabing, H., Yikang, H., 2015. Modelling and enhance control of DFIG under unbalanced grid voltage conditions. Electric Power Systems Research. 79(2): 272-281.

Jiabing, H., Yikang, H., Lie, X., Williams, W.B., 2015. Improve control of DFIG systems during network unbalance using PI-R current regulators. IEEE Transactions on Industrial Electronics. 56(2): 439-451.

Leonhard, W., 2001. Control of electric drives; Springer-Verlag, 3rd edition, USA.

Pham-Dinh, T., Nguyen-Thanh, H., 2013. Improving stability for independent power control of wind-turbine doubly fed induction generator during grid unbalance with PI-Fuzzy controller. Journal of The Japan Society of Applied Electromagnetics and Mechanies. 21(3): 425-429.

Pham-Dinh, T., Nguyen-Thanh, H., Uchida, K., Nguyen, G.M.T., 2013. Comparison between modifications of SFOC and PDC in control of grid-connected doubly fed induction generator under unbalanced voltage dip. Proceeding of SICE Annual Conference 2013, pp. 2581-2588, Nagoya Japan.

Pham-Dinh, T., Nguyen, A.N., Nguyen-Thanh, H., 2012. Improving stability for independent power control of wind turbine doubly fed induction generator with SFOC and DPC during grid unbalance. Proceeding of The 10th International Power and Energy Conference IPEC 2012, pp. 155-160, Ho Chi Minh City, Vietnam.

Srinadh, J., 2014. Dynamic Performance of DFIG using SMES For WECS. International Journal of Recent Development in Engineering and Technology. ISSN 2347-6435(Online). 3(1) 148 – 151.

Wenske, J., 2011. Special report direct drives and drive-train development trends. Wind Energy Report Germany 2011, Siemens Press Picture.

Xu, L., Wang, Y., 2007. Dynamic modeling and control of DFIG based wind turbines under unbalanced network conditions. IEEE Transactions of Power Systems. 22(1): 314–323.

Yikang, H., Jiabing, H., Rende, Z., 2005. Modelling and control of wind-turbine used DFIG under network fault conditions. Proceeding of the Eight International Conference on Electrical Machines and Systems ICEMS 2005. Vol. 2, pp. 986-991, Nanjing, China.