Nguyen Van Dat * , Huynh Lien Huong , Huynh Thanh Tuan , Ho Quoc Phong , Do Vo Anh Khoa , Nguyen Thanh Dat and Ronny Purwadi

* Corresponding author (nvdat@ctu.edu.vn)

Main Article Content

Abstract

The purpose of this present study is to make a fine tip Ca2+—selective electrode. Detection limit is found at pCa around 7.5 in Ca2+ buffer solution. The changes in EMF induced between two solutions for 10—fold change in Ca2+ concentration are close to 30 mV. This electrode characteristics were found for single—barrelled microelectrodes of 72.6 nm diameter tip and an internal filling solution buffered for pCa of 6.
Keywords: cocktail A, detection limit, ETGA, ISE, silanization

Article Details

References

Ammann, D., Bührer, T., Schefer, U., Müller, M., and Simon, W., 1987. Intracellular neutral carrier–based Ca2+ microelectrode with subnanomolar detection limit. European Journal of Physiology. 409(3): 223–228.

Ceresa, A., Bakker, E., Hattendorf, B., Gunther, D., and Pretsch, E., 2001. Potentiometrie Polymeric Membrane Electrodes for Measurements of Environmental Samples at Trace Levels: New Requirements for Selectivities and Measuring Protocols, and Comparison with ICPMS. Anal. Chem. 73: 343–351.

Eriksen, R.S., Mackey, D.J., van Dam, R., and Nowak, B., 2001. Copper speciation and toxicity in Macquarie Harbour, Tasmania: an investigation using a copper ion selective electrode. Mar Chem. 74(2–3): 99–113.

Fry, C.H., and Langley, S.E.M, 2002. Ion–Selective Electrodes for Biological Systems. CRC Press.

Greaves, G.N., Fontaine, A., Lagarde, P., Raoux, D. and Gurman, S.J., 1981. Local structure of silicate Glasses. Nature (Loud.). 293: 611–616.

Holland, L., 1964. The Properties of Glass Surfaces. Chapman and Hall, London.

Hu, J., Stein, A., and Buhlmann, P., 2016. Rational design of all–solid–state ion–selective electrodes and reference electrodes. Trends in Analytical Chemistry. 76: 102–114.

Miller JM., 2005. Chromatography: Concepts and Contrasts. John Wiley and Sons.

Korchev, Y.E., Bashford, C.L., Milovanovic, M., Vodyanoy, I., and Lab, M.J., 1997. Scanning Ion Conductance Microscopy of Living Cells. Biophysical Journal. 73(2): 653–658.

Rasmussen, MJ., 1972. Lecture for the Danish Society for Clinical Chemistry, Copenhagen.

Miller, A.J., Cookson, S.J., Smith, S.J. and Wells, D.M., 2001. The use of microelectrodes to investigate compartmentation and the transport of metabolized inorganic ions in plants. J. Exp. Bot. 52: 541–549.

Munoz, J.L., Deyhimi, F., and Coles, J.A., 1983. Silanization of glass in the making of ion–sensitive microelectrodes. Journal of Neuroscience Methods. 8: 231–247.

Hernandez R., Riu J., and Rius, FX.., 2010. Determination of calcium ion in sap using carbon nanotube­–based ion–selective electrodes. Analyst. 135: 1979–1985.

Tsien, R.Y. and Rink, T.J., 1981. Ca2+–selective electrode: a novel PVC–gelled neutral carrier mixture compared with other currently available sensors. J Neurosci Methods. 4: 73–86.

Vijayalakshmi, A., and Selvi, J.T., 2013. A new simple method for the preparation of calcium ion selective electrode and its analytical applications. Chemical Science Transaction. 2(S1): S246–S250.

Most read articles by the same author(s)